Heat pump error codes
An error code tells the engineer where to look.
Free, no obligation. One local company prices it, not five.
- L9Ecodan: low primary flow
- 7HDaikin: abnormal water flow
- U0Daikin: short of refrigerant
- 1 resetthen book a repair if it returns
Ecodan error codes
| Code | What it means | What it usually is |
|---|---|---|
| L3 | Circulation water overheat protection | Flow too low or the water too hot. Check the filter and pressure. |
| L5 | Indoor temperature sensor failure | A sensor (THW1 or THW2) needs testing and replacing. |
| L6 | Circulation water freeze protection | Water too cold in the unit. Check the flow and the outdoor unit. |
| L8 | Heating operation error | The system isn't reaching temperature. Needs a look. |
| L9 | Low primary flow rate | The most common call: low pressure, a blocked magnetic filter, air or a pump fault. |
| LP | Water flow out of range for the outdoor unit | Flow too low or too high through the outdoor unit. |
| P1 | Room temperature sensor failure | The room sensor (TH1) needs testing. |
| P6 | Anti-freeze protection of the heat exchanger | Low flow in cold weather. Check the filter and pressure. |
| E0 to E5 | Lost contact: main controller and the control board | Wiring or the controller. |
| E6 to EF | Lost contact: control board and the outdoor unit | Wiring, power to the outdoor unit or a board fault. |
| U and F codes | Outdoor unit failure | An engineer reads the outdoor unit's own code. |
From Mitsubishi Electric's own FTC controller tables. To clear a code, the manual has you switch the system off or press F4.
Daikin Altherma error codes
| Code | What it means | What it usually is |
|---|---|---|
| 7H | Abnormal water flow | Low pressure, a blocked filter, air or a stuck pump. |
| 80 / 81 | Inlet or outlet water sensor fault | A sensor needs testing or replacing. |
| 89 | Water heat exchanger freezing | Low flow in cold weather. Check the filter and pressure. |
| AA | Backup heater overheating | The backup heater's thermal cut-out has tripped. |
| C0 | Flow sensor or flow switch fault | The flow sensor needs testing. |
| E1 | Control board (PCB) defect | Needs an engineer. |
| E3 / H3 | High pressure switch | Often low flow or a blocked coil. Needs an engineer. |
| U0 | Shortage of refrigerant | A gas leak. Needs an F-gas certified engineer. |
| U4 | Indoor and outdoor units not talking | Wiring, power or a board fault. |
| UA | Indoor and outdoor units don't match | Usually after a part was replaced. |
From Daikin's own Altherma tables. Daikin codes often have a number after them (7H-01, U4-00), which narrows it down further for the engineer.
What to do with any code
- Write down the code and when it shows: at start-up, on hot water, in the cold.
- Check the pressure gauge and the outdoor unit (see the checks).
- Reset once: off at the isolator for a few minutes, then on.
- If it comes back, book a repair and give the engineer the code, the make and the model.
Samsung, Panasonic, LG, Grant and other makes have their own codes; the manual or the engineer reads them the same way.
Get a price with no obligation
Tap what you need and leave your number. It goes to one heat pump and air conditioning company that covers your county. They ring you back to arrange a visit and a written price.
Heat pump and air con repair guides & price breakdowns
Straight answers to what people ask most: itemised costs, specifications, planning or grants, and what to check before you book.
More guides & resources: The SEAI heat pump grant · Heat pump vs air conditioning · F-gas engineers · All guides & calculator hub · Technical & trade glossary · Frequently asked questions · All areas covered · About this site
Questions we get asked
What does L9 mean on a Mitsubishi Ecodan?
Low primary circuit flow rate, detected by the flow sensor. Usually low pressure, a blocked magnetic filter, air in the system or a pump fault.
What does 7H mean on a Daikin heat pump?
Abnormal water flow. The same usual causes: pressure, a blocked filter, air or the pump.
What does U4 mean on a Daikin?
The indoor and outdoor units have lost contact: wiring, power to the outdoor unit or a board fault.
Can I clear a heat pump error code myself?
You can reset it once. If it comes back, there's a fault to find.
Heat pump and air con repair across all 26 counties
Requests from all 26 counties go to one local specialist who covers your county — from Dublin, Cork, Galway and Limerick to Kildare, Meath, Wicklow, Waterford and Donegal. Pick your county below for local prices, specifications and advice. Compare all areas covered →
Get a free quote for your heat pump or air con
One company that covers your county rings you. Nothing is agreed until you accept a written price.